Separated Floor Joist With Full Depth Solid Blocking

If a pipe or duct vent passes through the floor, the double joists may be separated to allow the pipe or vent to pass through. In this illustration, full-depth solid blocking is required so that the two joists will function as a combined member without twisting. 2024 IRC R502.4(2).
If a pipe or duct vent passes through the floor, the double joists may be separated to allow the pipe or vent to pass through. In this illustration, full-depth solid blocking is required so that the two joists will function as a combined member without twisting. 2024 IRC R502.4(2).

License & High Resolution Download

All images copyright © 2008-2024 the International Association of Certified Home Inspectors, Inc. (InterNACHI). All rights reserved. InterNACHI grants its members a non-exclusive, non-transferable worldwide license, as long as they remain a member of InterNACHI. Non-members must obtain written or email permission from InterNACHI before using these images for any purpose. If you are an InterNACHI member or have received written or email permission to use this image, you may download it in high resolution.